ASTEC Industrial Partner

73-540-0020 - Astec 73-540-0020 MP4-2Q-00 400W Modular Industrial Power Supply; 24V/15A DC...

larger image

Request Quote
For Price
Part Number:
73-540-0020
Model Number:
73-540-0020
Make:
ASTEC
Lead Time:
Available
Qty In Stock:
Available

Astec 73-540-0020 MP4-2Q-00 400W Modular Industrial Power Supply; 24V/15A DC Output. 100-240V 7A 50/60/400Hz Frequency. Simple Type: Power Supply

Download the datasheet (PDF)

For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.

Features

  • CISPR 22, EN55022 Curve B conducted / radiated EMI
  • Current share on all outputs with ratings of 10 A or greater
  • European CE Mark requirements
  • Forced air cooling, field replaceable fan
  • Global and individual module inhibits/enable
  • Global DC OK signal and status indicator LED
  • IEC EN61000-3-2 harmonic distortion compliance
  • Immunity - EN61000 -4, -2, -3, -4 & -5 Level 3
  • Input-OK-signal and status indicator LED
  • Isolated 5 V bias voltage
  • Low leakage option for medical applications
  • Margining on all single output modules
  • Optional VME timing and system DC OK module
  • Overload protection on all outputs
  • Power factor correction
  • Remote sense on all outputs with ratings greater than 2 A
  • Voltage adjustment on all outputs

Specifications

    General
  • AC OK: >5 ms early warning min. before outputs lose regulation; Full cycle ride thru (50 Hz)
  • Adjustment range: ± 10% minimum all outputs
  • Bandwidth: limited to 20 MHz
  • DC OK: -2% to -8% of nominal for any monitored output
  • Dynamic response: < 2% or 100 mV, with 25% load step
  • Efficiency: 70 - 80% typ. @ full case load
  • EMI filter (low leakage option): CISPR 22/EN55022 Level “A”
  • EMI filter standard: CISPR 22/EN55022 Level “B”
  • Frequency: 47 - 440 Hz
  • Global Inhibit/Enable: TTL, Logic “1” and Logic “0”
  • Harmonic distortion: Meets EN61000-3-2
  • Holdover storage: 20 ms minimum (independent of input Vac)
  • Housekeeping Bias voltage: 5 Vdc @ 1.0 A max. present whenever AC input is a
  • Input fuse (internal): MP4 10 A; MP6
  • Input range: 85 - 264 Vac; 120 - 350 Vdc
  • Inrush Current: 40 A peak max. (soft start)
  • Isolation: Meets EN60950
  • Leakage current (low leakage option): 300µA max. @ 240 Vac
  • Leakage current standard: 2.0 mA max. @240 Vac
  • Margining: ± 4 - 6% nominal1
  • Minimum Load: Not required on single or triple output. 10% required on main of dual output
  • Module inhibit: TTL, isolated, singles and dual (both outputs) only
  • Output/Output isolation: >1 Megohm
  • Overall regulation: 0.4% or 20mV max.(36 W modules 4% maximum)
  • Overcurrent protection: Single output module & main output of dual output module 105-120% of rated output current. Aux output of dual output module 105-140% of rated output current
  • Pk-Pk: 1.0% or 50mV, whichever is greater
  • Power Factor: 0.99 typ. meets EN61000-3-2
  • Radiated EMI: CISPR 22/EN55022 Level “B”
  • Recovery time: To within 1% in < 300 µsec
  • Remote sense: Up to 0.5 V total drop (not avbl on triple output module)
  • Reverse voltage protection: 100% of rated output current
  • Ripple RMS: 0.1% or 10mV, whichever is greater
  • Single wire parallel: Current share to within 2% of total rated current
  • Switching frequency: 250k Hz
  • Thermal protection: All outputs disabled when internal temp exceeds safe operating range. > 5ms warning (AC OK signal) before shutdown
  • Turn-on time: AC on 1.5 sec typ. inhibit/enable 150 ms typ.

 

Applications

  • None Available

Aliases