ASTEC Industrial Partner

VS3-K2-B4-H255-00 - Astec VS3-K2-B4-H255-00 Power Supply - 8 inch, 1Ø, 750 W,...

larger image

Request Quote
For Price
Part Number:
VS3-K2-B4-H255-00
Model Number:
VS3-K2-B4-H255-00
Make:
ASTEC
Lead Time:
Available
Qty In Stock:
Available

Astec VS3-K2-B4-H255-00 Power Supply - 8 inch, 1Ø, 750 W, 5 V. See datasheet for more information. Simple Type: Power Supply

Download the datasheet (PDF)

For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.

Features

  • 2500 W with 3-phase input
  • 3 year warranty
  • AC-OK-signal (logics “1” or “0”)
  • CISPR 22, EN55022 Level B conducted / radiated EMI
  • Current share on all outputs
  • DC-OK signal and status indicator LED-on all outputs
  • EN61000 immunity standards
  • European CE Mark
  • Global and individual module inhibits/enable
  • Global DC OK (logics “1” or “0”)
  • IEC 555-2 harmonic distortion compliance
  • Margining on all outputs
  • Overload protection on all outputs
  • Power factor correction
  • Remote sense on all outputs
  • Voltage adjustment on all outputs

Specifications

    General
  • AC-OK warning time: >5 ms (power fail)
  • Adjustment range: ±10% minimum
  • DC OK: -2% to -6% of nominal
  • Dynamic response: 2% or 100 mV with 25% load step(any output)
  • Efficiency: 75% - 82%
  • EMI-filter: CISPR 22, EN55022 Level B conducted/radiated
  • Frequency: 47 to 440 Hz
  • Fuse rating: 600 V / 25 A (internal)1Ø | 250 V / 20 A (internal)3Ø
  • Holdover storage: 20 ms min. / 40 ms typical independent of VAC
  • Input Voltage: 85-264 VAC 1Ø | VS1, VS3 & VS4 (See operating curve on pg. 2
  • Inrush Current: 40 A peak max.
  • LEAKAGE CURRENT: 2 mA max. at 240 VAC
  • Line/load reg: 0.2% or 5 mV max.
  • Loss of phase: On VS6, VS8 & VS9, unit will continue to operate with loss of phase
  • Margining: ±4-6% nominal
  • Output/Output isolation: >1 Megohm
  • Overload Protection: Main: 105% to 120% of rated current | Auxiliaries:105% to 140%
  • Overvoltage: protection 2-5 V 122% to 134% of output voltage; 12-48 V 110% to 120%; recycle AC
  • Power Factor: 0.99 typical (0.9 on VS6, VS8 & VS9)
  • Recovery time: To within 1% in <300 µsec
  • Remote sense: Up to 0.5 V - total drop
  • Reverse voltage protection: 100% of rated output current
  • Ripple: RMS: 0.1% or 10 mV | P-P: 1.0% or 50 mV | Bandwidth limited to 20 MHz
  • Short Circuit Protection: Protected for continuous short circuit, recovery automatic
  • Single wire parallel: Current share to 2% of total rated current
  • Switching frequency: 200 KHz (900-1500 W module, 400 KHz)
  • Thermal protection: Each module thermally protected. Input module: auto recovery. Output modules; recycle AC.
  • Turn-on time: AC / 1 sec; Inhibit / 100 ms max.

 

Applications

  • None Available

Aliases

  • None Available