LPS175-C - Astec LPS175-C 130 Watt Linear/Switching Power Supply Simple Type: Power...
Request Quote
For Price
- Part Number:
- LPS175-C
- Model Number:
- LPS175-C
- Make:
- ASTEC
- Lead Time:
- Available
- Qty In Stock:
- Available
Astec LPS175-C 130 Watt Linear/Switching Power Supply Simple Type: Power Supply
For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.
Features
- 12 V Aux output
- 5 V standby output
- Active power factor correction
- Built-in EMI filter
- DC power good
- IEC EN61000-3-2 compliance
- Low output ripple
- Optional cover (-C suffix)
- Overload protection
- Overvoltage protection
- Power fail and remote inhibit
- Single wire current sharing
- Thermal overload protection
- Wide Range Adjustable output Remote sense on main output
Specifications
- Adjustment range: 2:1 wide ratio minimum
- Aux output: 12 V @ 1 A -5 %, +10%
- DC - OK: TTL logic signal goes high after main output is in regulation. It goes low when there is a loss of regulation
- Efficiency: 75% typical at full load
- Electromagnetic susceptibility: Designed to meet IEC EN61000-4, -2, -3, -4, -5, -6, -8, -11 Level 3
- EMI filter: FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B conducted; VDE 0878 PT3 Class B conducted
- Frequency: 47-63 Hz
- Hold-up time: 20 ms @175 W load at nominal line
- Humidity: Operating; non-condensing 5% to 95%
- Input range: 85-264 VAC; 120-300 VDC
- Inrush Current: 38 A max, cold start @ 25°C
- Low temperature start: -20°C
- Maximum power: 110 W convection (75 W with cover); 175 W with 30 CFM forced air (130 W with cover)
- MTBF demonstrated: >550,000 hours at full load and 25 °C ambient conditions
- Operating Temperature: 0° to 50°C ambient; derate each output at 2.5% per degree from 50° to 70 °C
- Overload Protection: Short circuit protection on all outputs. Case overload protected @ 110-145% above peak rating
- Overvoltage Protection: 10% to 40% above nominal output
- Power Factor: 0.99 typical
- Power failure: TTL logic signal goes high 100 - 500 msec after V1 output; It goes low at least 4 msec before loss of regulation
- Remote Inhibit: Requires contact closure to inhibit outputs
- Remote sense: Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected.
- Safety Ground Leakage Current: 1.0 mA @ 50/60 Hz, 264 VAC input
- Standby outputs: 5 V @ 2 A regulated ±5%
- Storage Temperature: -40° to 85°C
- Temperature Coefficient: ±0.4% per °C
- Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75G peak 5Hz to 500Hz, operational
Applications
- None Available
Aliases